DEDICATED PRESSURE SYSTEMS LTD.

Telephone 01372 803 675
Fax 01372 803 678
Email dps@heatweb.com
 
Internet http://www.heatweb.com

The Institute of Plumbing

R/O Shops, 9-19 Manor Green Road, Epsom, Surrey KT19 8RA
  

Installation Instructions
GX Stowaway

1605-2  14/03/01

Heat Bank Thermal Store System  
Stowaway advanced F+E  
Single Heat Exchanger (30 ltr/min)  
Directly heated from remote source  
40mm Foam Insulation  
GX-Plan primary controls  
Directly Pumped Heating Circuit  
RX1 Programmable Room Thermostat  
Fitted Primary Pump, 5m head  
All fitted controls are wired  
Manual Fill - No Overflow  
Thermostatic Blending Valve 22mm  
Basic Low Water Level Cut-Out  
Backup Immersion Heater  
Cased  


1   Integral Expansion Vessel (Unpressurised)
2   Plate Heat Exchanger
3   Heat Exchanger Pump
4   Flow Switch
6   Manual Air Vent
7   Automatic Air Vent
8   Integral Overflow Chamber
9   Store Filling Point
11  Y-Pattern Strainer (supplied loose)
13  Connection to Expansion Vessel
14  Immersion Heater 3kW Incaloy with Stat
16  Cold Mains In, 22mm
17  Hot Mains Out, 22mm
18  Drain Cock
19  Flow From Boiler
20  Return to Boiler
23  Flow to Heating Circuit
24  Return from Heating Circuit
28  Heating Circuit Pump UPS 15/60
33  Danfoss Radio Reciever
38  Cylinder Immersion Thermostat
39  White Coated Steel Casing
40  Tight Fitting Lid
41  Primary Blending Valve
54  Filling Loop (disconnect after use)
55  Water Level Switch
56  Manual Water Level Test and Drain
66  Overfill Drain Cock

 

Unit ID

SC-150-1605-2SC-180-1605-2

Capacity

150180

Base Diameter

450450

Overall Diameter

530530

Height

13301510

Contents:
1. Introduction
2. General Requirements
3. Mains Water Supply
4. Connections:
5. Wiring
6. Filling
7. Commissioning
8. Fault Finding
9. Servicing
10. Spares
11. User Instructions